Loading...
HomeMy WebLinkAboutB_692_PA_2017-01279 ti S Uarlos Delgado A R C H I T E C T i Oct 4, 2017 Supplemental Submittal for PA - 2017 r 01279 Subject Property Address: 69213 Street Map & Tax Lot: 391E 09AB; Tax Lot 7000 Property owner/ Bonnie and John Rinaldi Applicant: 692 B Street Ashland, OR 97520 1. I 1 Image of proposed structure with new dormer r ~f A 2~IN - h Y Photo of existing structure Material and paint color submittal per AMC 18.4.2.030.E Siding, roofing, trim, windows and colors to match existing: light blue and white 217 Fourth Street • Ashland, Oregon 97520 541.552.9502 carlos@CarlosDelgadoArchitect.com D 0; I 612" 10'.11/2'-9112° 15'-0' 9r~ 4460v QF _ 7,5;12 7.5:12 _ / Y 48X24 AWNING .-'SLOPE- r -SLOPE-- -J._ r-------- - - \ 24X21 AWN / r \ =f= 0( TEMP, HDT2 rv ® p N E E -j (E) (E) CIO ~ n u, (E) N \ ¢ N(~ n ,,d m N ROOF ROOF 9TOR ROOF 0~L'+ ( old: ~V ~N / ❑ Q~ o 9❑; BAJH U i R ® I 2r v 4- - m (E( ~0 ~0 E / CUT \V ( € 432 1~ W - ROOF ti~J n~G' ROOF •CC34N 7 4 A\ ( u y~ N (E) G ABLE TO 0 --,ER --_95 BE REMOVED A z ? 5 _s_ _____e~P@ OPEN ROOM A- 3'-3'-5~~ U o 1.fi:12 l_ _ cpv U x lL (E) `r a vi SLOPE ROOF BIFOLD+B, LE ET ( TH I( CLOS 4 1111 lI sTOR. za54ew REP o 12 II IV ONDEREAV q R S yp_~ {A GTO - - - - - - - - - - - - - C_ - Y Y 4 6 N a . a 7 4X44 EGRESS !dM 5,-5, N O R (E)OPENING q W N j a i ® EXISTING WALLS TO REMAIN -j NEWWALLS ROOF PLAN UPPER FLOOR PLAN C--~ WALLS TO BEREMOVFO SCALE: 114'=1'A' SCALE: 114'=V-0' NORTH I' - - - 0 4 B 12 CD p w 0 ® Z F-- o i" In ~ s p~ (E) SINK, w K W m Q - - - - - - - - - - REPLACE W =I wiNEwa E tLT E STO ORAGE zU, c 1 I YANf4Y O N W -..-h pNm CLG tB' W0 d I w 3w Z(D z yi - 1 I-)b.5° 1 CLG 13'6 Q d E taacXl M.1T 5% o w m rn li)128IFROD - BAT - . 3 LEAVE OPEN' 1 - 'y BELOW LNON ~I O (O W 14 J )I 0 ❑ AGQE89 1 N _0 1 Q IEI TOS S- ~ _ (E E SHOP J f ® OPEN ROOM z, L~ N ~>W3 z t I ~n CLG+14'5 d / GARAGE \ I, f a L [,as L f'L r---- - 4w II ~I FOR CONSTRUCTION r zgo it RAN ~H i~~ ~I DRAWN: CHECKED: GAS> x TS CD 2~ - I' L:H J13.L_ T~ AMP DATE: "°°`°m ELECT MP LL PANEL Q 9/14j17 2 --L 2 L_ J w - E) AS REL ATE - EPLACEDWITHSINGLE192'X84"" PROJECT: - - - - - - - - - - \ 82X001 EXISTING2GARAGE DOORS R _ 04 ~ (E)L)OOR jIITE,TEMP (E )ELECT TEMP RINALDI 17 MTR ( N SHEET I W -T, EXISTING WALLS TO REMAIN rq X NEWWNAS UPPER FLR ELECT/ LIGHTING PLAN MAIN FLOOR PLAN E--~ WALLS TO BE REMOVED A1.1 SCALE: 114'=1~0" NOMH OF SHEETS SCALE, 1/4°=1A" t I 0 4 8 12 L----L- - - CITY ® s il August 29, 2017 Notice of Final Decision On August 29, 2017, the Community Development Director approved the request for the following: Planning Action: PA-2017-01279 Subject Property: 692 B Street Applicant: Bonnie Rinaldi/Carlos Delgado Description: A request for Site Design Review approval to construct an accessory residential unit within the second story of the garage/shop building located at the rear of the property adjacent to the alley. The application includes the addition of a dormer on the east side of the building to provide additional floor space for the accessory residential unit. The Community Development Director's decision becomes final and is effective on the 12th day after the Notice of Final Decision is mailed. Approval is valid for a period of 18 months and all conditions of approval identified on the attached Findings are required to be met prior to project completion. The application, all associated documents and evidence submitted, and the applicable criteria are available for review at the Ashland Community Development Department, located at 51 Winburn Way. Copies of file documents can be requested and are charged based on the City of Ashland copy fee schedule. Prior to the final decision date, anyone who was mailed this Notice of Final Decision may request a reconsideration of the action as set forth in the Ashland Land Use Ordinance (ALUO) 18.5.1.050(F) and/or file an appeal to the Ashland Planning Commission as provided in ALUO 18.5.1.050(G). The ALUO sections covering reconsideration and appeal procedures are attached. The appeal may not be made directly to the Oregon Land Use Board of Appeals. If you have any questions regarding this decision, please contact Maria Harris in the Community Development Department at (541) 488-5305. cc: Parties of record and property owners within 200 ft COMMUNITY DEVELOPMENT DEPARTMENT Tel: 541488-5305 51 Winburn Way Fax: 541-552-2050 Ashland, Oregon 97520 TTY: 800-735-2900 L N4"___. d.or.us SECTION 18.5.1.050 Type I Procedure (Administrative Decision with Notice) E. Effective Date of Decision. Unless the conditions of approval specify otherwise or the decision is appealed pursuant to subsection 18.5.1.050.G, a Type I decision becomes effective 12 days after the City mails the notice of decision. F. Reconsideration. The Staff Advisor may reconsider a Type I decision as set forth below. 1. Any party entitled to notice of the planning action, or any City department may request reconsideration of the action after the decision has been made by providing evidence to the Staff Advisor that a factual error occurred through no fault of the party asking for reconsideration, which in the opinion of the Staff Advisor, might affect the decision. Reconsideration requests are limited to factual errors and not the failure of an issue to be raised by letter or evidence during the opportunity to provide public input on the application sufficient to afford the Staff Advisor an opportunity to respond to the issue prior to making a decision. 2. Reconsideration requests shall be received within five days of mailing the notice of decision. The Staff Advisor shall decide within three days whether to reconsider the matter. 3. If the Staff Advisor is satisfied that an error occurred crucial to the decision, the Staff Advisor shall withdraw the decision for purposes of reconsideration. The Staff Advisor shall decide within ten days to affirm, modify, or reverse the original decision. The City shall send notice of the reconsideration decision to affirm, modify, or reverse to any party entitled to notice of the planning action. 4. If the Staff Advisor is not satisfied that an error occurred crucial to the decision, the Staff Advisor shall deny the reconsideration request. Notice of denial shall be sent to those parties that requested reconsideration. G. Appeal of Type I Decision. A Type I decision may be appealed to the Planning Commission, pursuant to the following: 1. Who May Appeal. The following persons have standing to appeal a Type I decision. a. The applicant or owner of the subject property. b. Any person who is entitled to written notice of the Type I decision pursuant to subsection 18.5.1.050.B. c. Any other person who participated in the proceeding by submitting written comments on the application to the City by the specified deadline. 2. Appeal Filing Procedure. a. Notice of Appeal. Any person with standing to appeal, as provided in subsection 18.5.1.050.G.1, above, may appeal a Type I decision by filing a notice of appeal and paying the appeal fee according to the procedures of this subsection. The fee required in this section shall not apply to appeals made by neighborhood or community organizations recognized by the City and whose boundaries include the site. If an appellant prevails at the hearing or upon subsequent appeal, the fee for the initial hearing shall be refunded. b. Tine for Filing. A notice of appeal shall be filed with the Staff Advisor within 12 days of the date the notice of decision is mailed, c. Content of Notice ofAppeal. The notice of appeal shall be accompanied by the required filing fee and shall contain, i. An identification of the decision being appealed, including the date of the decision. ii. A statement demonstrating the person filing the notice of appeal has standing to appeal. iii. A statement explaining the specific issues being raised on appeal. iv. A statement demonstrating that the appeal issues were raised during the public comment period. d. The appeal requirements of this section must be fully met or the appeal will be considered by the City as a jurisdictional defect and will not be heard or considered. 3.. Scope of Appeal. Appeal hearings on Type 1 decisions made by the Staff Advisor shall be de novo hearings before the Planning Commission. The appeal shall not be limited to the application materials, evidence and other documentation, and specific issues raised in the review leading up to the Type I decision, but may include other relevant evidence and arguments. The Commission may allow additional evidence, testimony, or argument concerning any relevant ordinance provision. 4. Appeal Hearing Procedure. Hearings on appeals of Type I decisions follow the Type II public hearing procedures, pursuant to section 18.5.1.060, subsections A - E, except that the decision of the Planning Commission is the final decision of the City on an appeal of a Type I decision. A decision on an appeal is final the date the City mails the adopted and signed decision. Appeals of Commission decisions must be filed with the State Land Use Board of Appeals, pursuant to ORS 197.805 - 197.860. COMMUNITY DEVELOPMENT DEPARTMENT Tel: 541-488-5305 51 Winburn Way Fax: 541-552-2050 Ashland, Oregon 97520 TTY: 800-735-2900 ww v.ashland.onus ASHLAND PLANNING DIVISION FINDINGS & ORDERS i PLANNING ACTION: PA-2017-01279 SUBJECT PROPERTY: 692 B St. O ER/APPLICANT: Bonnie Rinaldi/Carlos Delgado DESCRIPTION: A request for Site Design Review approval to construct an accessory residential unit within the second story of the garage/shop building located at the rear of the property adjacent to the alley. The application includes the addition of a dormer on the east side of the building to provide additional floor space for the accessory residential unit. COMPREHENSIVE PLAN DESIGNATION: Low Density Multiple-Family Residential; ZONING: R-2; ASSESSOR'S MAP: 39 lE 09 AB; TAX LOTS:7000 SUBMITTAL DATE: July 7, 2017 DEEMED COMPLETE DATE: July 20, 2017 STAFF APPROVAL DATE: August 29, 2017 APPEAL DEADLINE (4:30 P.M.) September 11, 2017 FINAL DECISION DATE: September 12, 2017 APPROVAL EXPIRATION DATE: March 11, 2019 DECISION The proposal is a request for Site Design Review to construct an accessory residential unit within the second story of the garage/shop building at the rear of the property adjacent to the alley and to add a dormer to east side of the building to provide additional floor space for the accessory residential unit. The proposed accessory unit is 385 square feet in size. The property is located in the Low Density Multiple-Family Residential zone (R-2) and in the Historic District. The subject property is located at the southwest corner of the intersection of B St. and Sixth St. The subject property and surrounding area are zoned Low Density Multiple-Family Residential (R-2) and located in the Railroad Addition Historic District. The neighborhood is comprised primarily of single-family and multi- family homes, many of which are designated as historic contributing structures. The lot is 13,400 square feet in size. The alley to the south of the lot provides vehicle access to the subject property. The property contains an existing, two-story residence facing B St., a detached single car garage near the Sixth St. property border and a separate garage/shop building at the rear of the property. The property contains mature landscaping and a variety of trees. The primary home on the property is a large two-story wood frame vernacular dwelling that was built in 1888. The City of Ashland's historic resources inventory identifies the home as historic contributing. The application is required to meet the approval criteria for Site Design Review in AMC 18.5.2.050 for the conversion of the second story space in the garage/studio structure to an accessory residential unit and the addition of a dormer on the east side of the building to provide additional floor space for the accessory PA #2017-01279 692 B St./mh Page 1 residential unit. The proposal is subject to the site development and design standards for multi-family residential development and the Historic District Design Standards in AMC 18.4.2.050.13. The proposal is to modify the upper level of the shop space to accommodate a 385-square foot accessory residential unit. The footprint of the building was not change and the exterior building modifications are limited to the addition of the dormer on the second story of the shop building and the addition of a new door to access the accessory residential unit on the south side of the garage/shop building. No trees are proposed for removal and the application includes a tree protection plan. The rear yard setback can be reduced to four feet for an accessory building located on an alley if the structure is no more than 15 feet in height. The garage/shop building is less than 15 feet in height with the addition of the dormer and therefore meets the rear yard setback exception. The garage/shop building is eight feet from the rear property line which exceeds the required four feet. The garage/shop building meets the required side and front yard setback requirements. The allowed lot coverage for the R-2 zone is 65 percent of the lot and the subject property has 32 percent coverage. The existing garage/shop building predates the maximum permitted floor area (MPFA) requirement. However, detached accessory buildings are exempt from the MPFA requirements if they are separated from the primary dwelling by six feet or more. The garage/shop building is separated by more than 15 feet from the primary dwelling. The primary residence requires two off-street parking spaces and the accessory residential unit requires one off-street parking space. There are two parldng spaces located in the garage/shop building. The third space is provided by an on-street parking credit on Sixth St. Two bicycle parking spaces are required for the accessory residential unit and the application indicates that bicycle parking is provided inside the garage. The proposal is required to have an outdoor space for recreational use of the tenants of the development equal to at least eight percent of the total lot area or in this case, 1,072 square feet. An outdoor area for the residents of the ARU that is 250 square feet in size is designated on the site plan between the garage/studio building and Sixth St. In addition, a large landscaped yard to the west of the primary residence serves as outdoor recreational space. The square footage of the accessory residential unit is exempt from the maximum permitted floor area calculation per AMC 18.2.5.070.E. because it is located more than six feet from the primary residence. At the closest point, the accessory residential unit is approximately 15 feet from the primary residence. The Historic Commission reviewed the application at the August 2, 2017 meeting and recommended approval of the application. The applicant indicated at the meeting that the new dormer exterior will match the shingles on the existing garage/shop building. The approval criteria for Site Design Review are in AMC 18.5.2.050 as follows: An application for Site Design Review shall be approved if the proposal meets the criteria in subsections A, B, C, and D below. The approval authority may, in approving the application, impose conditions of approval, consistent with the applicable criteria. A. Underlying Zone. The proposal complies with all of the applicable provisions of the underlying zone (part 18.2), including but not limited to: building and yard setbacks, lot area and dimensions, density and floor area, lot coverage, building height, building orientation, architecture, and other applicable PA #2017-01279 692 B St./mh Page 2 standards. B. Overlay Zones. The proposal complies with applicable overlay zone requirements (part 18.3). C. Site Development and Design Standards. The proposal complies with the applicable Site Development and Design Standards of part 18.4, except as provided by subsection E, below. D. City Facilities. The proposal complies with the applicable standards in section 18.4.6 Public Facilities and that adequate capacity of City facilities for water, sewer, electricity, urban storm drainage, paved access to and throughout the property, and adequate transportation can and will be provided to the subject property. E. Exception to the Site Development and Design Standards. The approval authority may approve exceptions to the Site Development and Design Standards of part 18.4 if the circumstances in either subsection 1 or 2, below, are found to exist. 1. There is a demonstrable difficulty meeting the specific requirements of the Site Development and Design Standards due to a unique or unusual aspect of an existing structure or the proposed use of a site; and approval of the exception will not substantially negatively impact adjacent properties; and approval of the exception is consistent with the stated purpose of the Site Development and Design; and the exception requested is the minimum which would alleviate the difficulty.; or 2. There is no demonstrable difficulty in meeting the specific requirements, but granting the exception will result in a design that equally or better achieves the stated purpose of the Site Development and Design Standards. The application with the attached conditions complies with all applicable City ordinances. Planning Action 2017-01279 is approved with the following conditions. Further, if any one or more of the following conditions are found to be invalid for any reason whatsoever, then Planning Action 2017-01279 is denied. The following conditions are attached to the approval. 1) That all proposals of the applicant shall be conditions of approval unless otherwise modified herein. 2) That the following items shall be submitted for review and approval of the Ashland Planning Division prior to the issuance of the building permit. a) That the tree protection fencing shall be installed according to the approved plan prior to any site work, storage of materials or issuance of the building permit. The tree protection shall be inspected and approved by the Ashland Planning Division prior to site work, storage of materials or the issuance of a building permit. The tree protection shall be chain link fencing six feet tall and installed in accordance with AMC 18.4.5.030.C. b) That a separate address for the accessory residential unit shall be applied for approved by the City of Ashland Engineering Division. Addressing shall meet the requirements of the Ashland Fire Department and be visible from the Public Right-of-Way. i 3) That the plans submitted for the building permit shall be in substantial conformance with those approved as part of this application. If the plans submitted for the building permit are not in substantial conformance with those approved as part of this application, an application to modify the PA #2017-01279 692 B St./mh Page 3 Site Review approval shall be submitted and approved prior to issuance of a building permit. 4) That the building permit submittals shall include the following information and revisions. a) The exterior building materials and paint colors shall be identified on the building plans and shall not be very bright primary or neon paint colors in accordance with AMC 18.4.2.030.E. j b) That the bicycle parking and access for the accessory residential unit in the garage shall be included and meet the design and dimensional requires of AMC 18.4.3.070. C) That storm water from all new impervious surfaces and runoff associated with peals rainfalls must be collected on site and channeled to the City storm water collection system (i.e., curb gutter at public street, public storm pipe or public drainage way) or through an approved alternative in accordance with Ashland Building Division policy BD-PP-0029. On-site collection systems shall be detailed on the building permit submittals. 5) That all necessary building permits, including permits for the new electrical service to the accessory residential unit, and system development charges for water, sewer, storm water, parks, and transportation shall be paid prior to the issuance of a building permit. 6) That prior to the issuance of the certificate of occupancy the following shall be completed. a) That a separate electric service and meter for the accessory residential unit shall be installed in accordance with Ashland Electric Department requirements, b) That the outdoor recreational space for the accessory residential unit as shown on the site plan submitted with the application shall be installed and accessible to the residents of the accessory residential unit. c) That recycle and refuse containers for the accessory residential unit shall be screened from adjacent properties and public right-of-ways. AA L August 29, 2017 Bill Molnar; Community Development Director Date Department of Community Development PA #2017-01279 692 B St./mb Page 4 AFFIDAVIT OF MAILING STATE OF OREGON ) County of Jackson ) The undersigned being first duly sworn states that: 1. 1 am employed by the City of Ashland, 20 East Main Street, Ashland, Oregon 97520, in the Community Development Department. 2. On August 29, 20171 caused to be mailed, by regular mail, in a sealed envelope with postage fully prepaid, a copy of the attached planning action notice to each person listed on the attached mailing list at such addresses as set forth on this list under each person's name for Planning Action #PA-2017-01279, 692 B Street. Signature of Employee C:IUserslsmithda.AFNHEIDesktopWFIDAVIT OF MAILING _Dana.d= 612912017 i PA-2017-01279 391 E09AC 3300 PA-2017-01279 391 E09AB 3701 PA-2017-01279 391 E09AB 3600 ADAMS FRANCES M (TOD) PA-2017- ADDERSON BUILDERS INC PA-2017- CAIN ROBERT ROY TRUSTEE ET AL PA- 01279 01279 2017-01279 157 SIXTH ST 234 VISTA ST 671 B ST ASHLAND, OR 97520 ASHLAND, OR 97520 ASHLAND, OR 97520 i PA-2017-01279 391 E09AC 3900 PA-2017-01279 391 E09AC 4000 PA-2017-01279 391 E09AB 7200 CARMICHAEL LYNNE TRSTEE FBO PA- CONKLIN LYN E TRUSTEE PA-2017- CROW CONSTANCE (CONNIE) E 2017-01279 01279 TRUSTEE ET AL PA-2017-01279 416 GREENFIELD AVE 3120 SOUTH STAGE RD PO BOX 1131 SAN ANSELMO, CA 94960 MEDFORD, OR 97501 ASHLAND, OR 97520 PA-2017-01279 391 E09AC 25 PA-2017-01279 391 E09AB 3200 PA-2017-01279 391 E09AC 3000 00 ELLIS CATHERINE E TRUSTEE ET AL PA- FITCH FAMILY PROPERTIES LLC PA- DENONWILLOW PA-2017-01279 2017-01279 2017-01279 132 SIXTH ST 743 B ST 7525 ADAMS RD ASHLAND, OR 97520 ASHLAND, OR 97520 TALENT, OR 97540 PA-2017-01279 391 E09AC 2100 PA-2017-01279 391 E09AC 2200 PA-2017-01279 391 E09AC 2400 GREENEWOOD HOMES LLC PA-2017- HUNG EPING/HUANG ANNE PA-2017- JOHNSON STEPHANIE L PA-2017-01279 01279 01279 329 GRANDVIEW P 0 BOX 516 156 SIXTH ST ASHLAND, OR 97520 ASHLAND, OR 97520 ASHLAND, OR 97520 PA-2017-01279 391 E09AC 2000 PA-2017-01279 391 E09AB 3800 PA-2017-01279 391 E09AC 2101 LANG PHILIP C TRUSTEE ET AL PA-2017- LAPKIN LAWRENCE TRUSTEE ET AL PA- LOOP KAREN M PA-2017-01279 01279 2017-01279 164 SIXTH ST 758 B ST PO BOX 1918 ASHLAND, OR 97520 ASHLAND, OR 97520 TAHOE CITY, CA 96145 PA-2017-01279 391 E09AC 2300 PA-2017-01279 391 E09AC 3100 PA-2017-01279 391 E09AB 7100 MARRS KATHLEEN ANN PA-2017-01279 MCINTYRE MARTHA M REV LIV TRUST ORE SHAKESPEARE FEST ASSOC PA- 150 SIXTH ST ET AL PA-2017-01279 2017-01279 ASHLAND, OR 97520 58 FOURTH ST P 0 BOX 158 ASHLAND, OR 97520 ASHLAND, OR 97520 PA-2017-01279 391 E09AB 3500 PA-2017-01279 391 E09AB 7300 PA-2017-01279 391 E09AB 3900 PEARSON EDWIN E TRUSTEE ET AL PA- PERLOFF FRED R/LAURA E PA-2017- PIKER EILEEN PA-2017-01279 2017-01279 01279 625 B ST 843 E MAIN ST 101A 164 5TH ST ASHLAND, OR 97520 MEDFORD, OR 97504 ASHLAND, OR 97520 PA-2017-01279 391 E09AB 4000 PA-2017-01279 391 E09AC 2600 RENWICK ALLISON TRUST ET AL PA- RINAL I BONN NIE 391 E09AB 7000 ROSS CAROL M TRUSTEE ET AL PA- 2017-01279 692 B ST BON 2017-01279 692 B S 236 FIFTH ST ASHLAND, OR 97520 120 SIXTH ST ASHLAND, OR 97520 ASHLAND, OR 97520 PA-2017-01279 391 E09AC 3200 PA-2017-01279 391 E09AB 3400 PA-2017-01279 391 E09AC 3800 STONE GLORIA I TRUSTEE ET AL PA- I STILES GLENNA SUE PA-2017-01279 2017-01279 YANG JAMES PA-2017-01279 725 B ST 153 SIXTH ST 156 FIFTH ST 2 ASHLAND, OR 97520 ASHLAND, OR 97520 ASHLAND, OR 97520 PA-2017-01279 692 B STREET DELGADO CARLOS 08-29-2017 217 FOURTH ST 28 ASHLAND, OR 97520 Planning Department, 51 Winbwo Way, Ashland, Oregon 97520 541-488-5305 Fax: 541-552-2050 www.ashland.or.us TTY: 1-800-735-2900 NOTICE OF APPLICATION PLANNING ACTION: 2017-01279 SUBJECT PROPERTY: 692 B Street OWNERIAPPLICANT: Bonnie Rinaldi/Carlos Delgado DESCRIPTION: A request for Site Design Review approval to construct an accessory residential unit within the second story of the garage/shop building at the rear of the property adjacent to the alley. The application includes the addition of a dormer on the east side of the building (facing Sixth St.) to provide additional floor space for the accessory residential unit. COMPREHENSIVE PLAN DESIGNATION: Low Density Multi-Family Residential; ZONING: R-2; ASSESSOR'S MAP : 391 E 09AB; TAX LOT: 7000 NOTICE OF COMPLETE APPLICATION: July 20, 2017 DEADLINE FOR SUBMISSION OF WRITTEN COMMENTS: August 3, 2017 NOTE: The Ashland Historic Commission will also review this Planning Action on Wednesday August 2, 2017 at 6:00 PM in the Community Development and Engineering Services building (Siskiyou Room), located at 51 Winburn Way. 97, 693 rPA2 723 15T ` 1Ed 164 739 153 ( 156 The Ashland Planning Division Staff has received a complete application for the property noted above. Any affected property owner or resident has a right to submit written comments to the City of Ashland Planning Division, 51 Winburn Way, Ashland, Oregon 97520 prior to 4:30 p.m. on the deadline date shown above. Ashland Planning Division Staff determine if a Land Use application is complete within 30 days of submittal. Upon determination of completeness, a notice is sent to surrounding properties within 200 feet of the property submitting application which allows for a 14 day comment period. After the comment period and not more than 45 days from the application being deemed complete, the Planning Division Staff shall make a final decision on the application. A notice of decision is mailed to the same properties within 5 days of decision. An appeal to the Planning Commission of the Planning Division Staffs decision must be made in writing to the Ashland Planning Division within 12 days from the date of the mailing of final decision. (AMC 18.5.1.050.G) The ordinance criteria applicable to this application are attached to this notice. Oregon law states that failure to raise an objection concerning this application, by letter, or failure to provide sufficient specificity to afford the decision maker an opportunity to respond to the issue, precludes your right of appeal to the Land Use Board of Appeals (LUBA) on that issue. Failure to specify which ordinance criterion the objection is based on also precludes your right of appeal to LUBA on that criterion. Failure of the applicant to raise constitutional or other issues relating to proposed conditions of approval with sufficient specificity to allow this Department to respond to the issue precludes an action for damages in circuit court. A copy of the application, all documents and evidence relied upon by the applicant and applicable criteria are available for inspection at no cost and will be provided at reasonable cost, if requested. All materials are available at the Ashland Planning Division, Community Development & Engineering Services Building, 51 Winburn Way, Ashland, Oregon 97520. If you have questions or comments concerning this request, please feel free to contact the Ashland Planning Division at 541-488-5305. G:\conun-dev\planning\Planning Actions\Noticing Folder\Mailed Notices & Signs\2017\FA-2017-01279.docz SITE DESIGN AND USE STANDARDS 18.5.2.050 The following criteria shall be used to approve or deny an application: A. Underlying Zone: The proposal complies with all of the applicable provisions of the underlying zone (part 18.2), including but not limited to: building and yard setbacks, lot area and dimensions, density and floor area, lot coverage, building height, building orientation, architecture, and other applicable standards. B. Overlay Zones: The proposal complies with applicable overlay zone requirements (part 18.3). C. Site Development and Design Standards: The proposal complies with the applicable Site Development and Design Standards of part 18.4, except as provided by subsection E, below. D. City Facilities: The proposal complies with the applicable standards in section 18A.6 Public Facilities and that adequate capacity of City facilities for water, sewer, electricity, urban storm drainage, paved access to and throughout the property and adequate transportation can and will be provided to the subject property. E. Exception to the Site Development and Design Standards. The approval authority may approve exceptions to the Site Development and Design Standards of part 18A if the circumstances in either subsection 1 or 2, below, are found to exist. 1. There is a demonstrable difficulty meeting the specific requirements of the Site Development and Design Standards due to a unique or unusual aspect of an existing structure or the proposed use of a site; and approval of the exception will not substantially negatively impact adjacent properties; and approval of the exception is consistent with the stated purpose of the Site Development and Design; and the exception requested is the minimum which would alleviate the difficulty.; or 2. There is no demonstrable difficulty in meeting the specific requirements, but granting the exception will result in a design that equally or better achieves the stated purpose of the Site Development and Design Standards. GAcomm-dev\planningTianning Actions\Noticing FolderWailed Notices S Signs\2017\FA-2017-01279.docx AFFIDAVIT OF MAILING STATE OF OREGON ) County of Jackson ) The undersigned being first duly sworn states that: 1. 1 am employed by the City of Ashland, 20 East Main Street, Ashland, Oregon 97520, in the Community Development Department.] I 2. On July 20, 20171 caused to be mailed, by regular mail, in a sealed j envelope with postage fully prepaid, a copy of the attached planning action notice to each person listed on the attached mailing list at such addresses as set forth on this list i under each person's name for Planning Action #PA-2017-01279, 692 B Street. Signature of Employee G:Icomm-devlplanninglTemplateslTEMPLATE_Affidavit of Mailing-Planning Acton Nofice.dotK 7120/2017 IIY PA-2017-01279 391 E09AC 3300 PA-2017-01279 391 E09AB 3700 PA-2017-01279 391 E09AB 3600 ADAMS FRANCES M (TOD) ADDERSON BUILDERS INC CAIN ROBERT ROY TRUSTEE ET AL 157 SIXTH ST 234 VISTA ST 671 B ST ASHLAND, OR 97520 ASHLAND, OR 97520 ASHLAND, OR 97520 PA-2017-01279 391 E09AC 3900 PA-2017-01279 391 E09AC 4000 PA-2017-01279 391 E09AB 7200 CARMICHAEL LYNNE TRSTEE FBO CONKLIN LYN E TRUSTEE CROW CONSTANCE (CONNIE) E 416 GREENFIELD AVE 3120 SOUTH STAGE RD TRUSTEE ET AL I SAN ANSELMO, CA 94960 MEDFORD, OR 97501 PO BOX 1131 ASHLAND, OR 97520 PA-2017-01279 391 E09AC 2500 PA-2017-01279 391 E09AB 3200 PA-2017-01279 391 E09AC 3000 DENON WILLOW ELLIS CATHERINE E TRUSTEE ET AL FITCH FAMILY PROPERTIES LLC 132 SIXTH ST 743 B ST 7525 ADAMS RD ASHLAND, OR 97520 ASHLAND, OR 97520 TALENT, OR 97540 PA-2017-01279 391 E09AC 2100 PA-2017-01279 391 E09AC 2200 PA-2017-01279 391 E09AC 2400 GREENEWOOD HOMES LLC HUNG EPING/HUANG ANNE JOHNSON STEPHANIE L P 0 BOX 516 156 SIXTH ST 329 GRANDVIEW; ASHLAND, OR 97520 ASHLAND, OR 97520 ASHLAND, OR 97520 PA-2017-01279 391 E09AC 2000 PA-2017-01279 391 E09AB 3800 PA-2017-01279 391 E09AC 2101 LANG PHILIP C TRUSTEE ET AL LAPKIN LAWRENCE TRUSTEE ET AL LOOP KAREN M 758 B ST PO BOX 1918 164 SIXTH ST ASHLAND, OR 97520 TAHOE CITY, CA 96145 ASHLAND, OR 97520 PA-2017-01279 391 E09AC 2300 PA-2017-01279 391 E09AC 3100 PA-2017-01279 391 E09AB 7100 MARRS KATHLEEN ANN MCINTYRE MARTHA M REV LIV TRUST ORE SHAKESPEARE FEST ASSOC 150 SIXTH ST ET AL P 0 BOX 158 ASHLAND, OR 97520 58 FOURTH ST ASHLAND, OR 97520 ASHLAND, OR 97520 PA-2017-01279 391 E09AB 3500 PA-2017-01279 391 E09AB 7300 PA-2017-01279 391 E09AB 3900 PEARSON EDWIN E TRUSTEE ET AL PERLOFF FRED R/LAURA E PIKER EILEEN 843 E MAIN ST 101A 164 5TH ST 625 B ST MEDFORD, OR 97504 ASHLAND, OR 97520 ASHLAND, OR 97520 PA-2017-01279 391 E09AB 4000 PA-2017-01279 391 E09AB 7000 PA-2017-01279 391 E09AC 2600 RENWICK ALLISON TRUST ET AL RINALDI JOHN R TRUSTEE JR ET AL ROSS CAROL M TRUSTEE ET AL 236 FIFTH ST 692 B ST 120 SIXTH ST ASHLAND, OR 97520 ASHLAND, OR 97520 ASHLAND, OR 97520 PA-2017-01279 391 E09AB 3300 PA-2017-01279 391 E09AC 3200 PA-2017-01279 391 E09AC 3800 STILES GLENNA SUE STONE GLORIA I TRUSTEE ET AL YANG JAMES 725 B ST 153 SIXTH ST 156 FIFTH ST 2 ASHLAND, OR 97520 ASHLAND, OR 97520 ASHLAND, OR 97520 k: PA-2017-01279 PA-2017-01279 391 E09AB 7000 692 B Street DELGADO CARLOS RINALDI BONNIE 07-20-2017 NOC 217 Fourth St 692 B Street 29 ASHLAND, OR 97520 ASHLAND, OR 97520 HN z y u v ni e j x` i n I i f 3M 20W 2101 2200, 33100 .2300 2400 -H Jl 2.8 M t r Planning Division ZONING PERMIT APPLICATION t \ 51 Winburn Way, Ashland OR 97520 ryry y FILE :SHLAICID 541-488-5305 Fax 541-488-6006 DESCRIPTION OF PROJECT i DESCRIPTION OF PROPERTY Pursuing LEEDO Certification? ❑ YES ❑ NO Street Address Assessor's Map No. 39 1 E Tax Lot(s) Zoning Comp Plan Designation APPLICANT / Z Name [ 6 &Aft Phone G E-Mail S M Address l City Zip tl PROPERTY OWNER 2 1' WO 2- Name Phone E-Mail bo 4h d -e a lI vet 44k Address City Zip 1 SURVEYOR ENGINEER ARCHITECT LANDSCAPE ARCHITECT OTHER Title Name Phone E-Mail dress City Zip Title Name Phone E-Mail Address City Zip I hereby certify that the statements and information contained in this application, including the enclosed drawings and the required findings of fact, are in all respects, true and correct. I understand that all property pins must be shown on the drawings and visible upon the site inspection. In the event the pins are not shown or their location found to be incorrect, the owner assumes full responsibility. I further understand that if this request is subsequently contested, the burden will be on me to establish: 1) that I produced sufficient factual evidence at the hearing to support this request; 2) that the findings of fact furnished justifies the granting of the request 3) that the findings of fact furnished by me are adequate; and further 7 4) that all structures or improvements are properly located on the ground. Failure egard will result most likely in not only the request being set aside, but also possibly in my structures being built in reliance thereon being required to be r oved my a ense. If I have any doubts, I am advised to seek competent professional advice an assista e. 7/L 1-7 A t'S Signature Date i As ner of the property involved in this request, I have read and understood the complete application and its consequences to me as a property o r. 11 roperty Owner Signature (required) Date [ro be completed by City Staff] Zoning Permit Type Filing Fee $ 1 6~ Date Received -7_ r OVER 0 GAcomm-dcv\planning\Forms & ]Handouts\Zoning Permit Application.doc 1 Jahn and Bonnie Rinaldi i 692 B Street Ei I f ~ F ROGUE PLANNING & DEVELOPMENT SERVICES, LLC July 7, 2017 i Site Review approval for an Accessory Residential Unit c Subject Property Address: 692 B Street Map & Tax Lot: 39 1E 09AB: Tax Lot 7000 Property Owner: Italian Trust John and Bonnie Rinaldi Trustee 692 B Street Ashland, OR 97520 Planning Consultant: Rogue Planning and Development Services Amy Gunter 1424 S Ivy Street Medford, OR 97501 541-951-4020 Architect: Carlos Delgado Architect 217 Fourth Street Ashland, OR 97520 Lot Information: Lot Area: 13,400 square feet Existing Residence: 2,076 square feet Detached, single car garage: 220 square feet Garage/ Shop building: 1,476 square feet Lot Coverages: Structures: 3,016 square feet Driveways, Pathways, Patios: 1,288 square feet Existing Lot Coverage: 4,304 square feet Page 1 of 12 Project Proposal: The request is for a Site Design Review Permit to allow for an Accessory Residential Unit within the upper floor of the detached garage/shop building at the rear of the property located adjacent to the alley. Property Description: The subject property is at 692 B Street. The property is at the southwest corner of the intersection of B Street and Sixth Street. The property contains an existing, two-story, historic r r ~s' contributing residence with a detached single car garage and a separate garage/shop building with a %2 story, upper level. 7/1001, 70b0 P A 9 At 0. 1 fie The subject property is zoned multifamily (R-2), other properties / in the vicinity are also zoned R-2 and E-1 with residential overlay. / r 1 i The adjacent properties are occupied by residential uses and their associated accessory structures. 3 The landscaping and trees on the property are in excellent a condition. There is a driveway curb cut from Sixth Street onto the subject property but it is not utilized. The parking for the property is accessed from the alley along the south property line. B Street is a fully improved right-of-way. B Street has a 60-foot wide right-of-way and is improved with curb, gutter, sidewalk and an eight-foot landscape parkrow along the frontage of the property. Sixth Street is also fully improved. Fifth Street has a 60-foot wide right-of-way and is also improved with curb, gutter, sidewalk and landscape parkrow. There are street trees in the landscape parkrows. The landscaping on the property is in excellent condition and will replaced in an equivalent manner if damaged by construction. There are two small diameter Coffee trees near the structure. These trees will be protected during construction. Public facilities exist in the right-of-way that service the property. Proposal: The proposal is to modify the upper level shop space to accommodate the provisions for a small accessory residential unit. No additions to the footprint of the building are proposed. The strategy is to enlarge the existing habitable space in the upper level from 288 square feet to 385 square foot by altering the gable dormer on the east elevation to become a shed dormer. The alteration adds 97 square feet of living space. Page 2 of 12 The ARU is to be accessed through a new entry door to be installed on the south wall of the shop building to the left of the garage doors. The entrance is within a fenced courtyard, approximately 10-feet from the rear property line. t Setbacks: The garage / shop building is pre-existing. It was constructed in the 1990s under permit of the City of Ashland. The structure is setback three-feet from the west, side property line and eight feet from the south, rear property line that abuts the alley. The setbacks are not proposed to be altered as part of the proposal. Maximum Permitted Floor Area: The accessory residential unit appears to be exempt from the maximum permitted floor area calculations. In the R-2 zone, accessory structures and accessory residential units are listed as exemptions from MPFA in section 18.2.5.070.E. Parking, Access, Circulation: Two off street parking spaces are required for the primary residence and they are provided within the garage. The 385-square foot unit requires one off-street parking space. The space is requested as an on- street parking credit on Sixth Street. Bicycle parking spaces are proposed within the garage. Trees and Landscaping: The existing landscaping is in excellent condition. There are two small stature coffee trees that will be protected throughout the duration of construction. To the east of the structure an outdoor area will be designated for the tenant of the ARU. The code requires 1,072 square feet of open space for the use of the tenants is provided. There substantially more than eight percent of the lot area devoted to open space for use by then tenants. F On the following pages, findings of fact addressing the criteria from Ashland Municipal Code are provided on the following pages. For clarity, the criteria are in Times New Roman font and t he applicant's responses are in Calibri font. Page 3 of 12 CRITERIA from the Ashland Land Use Ordinance 18.5.2.050 Site Design Review A. Underlying Zone. The proposal complies with all of the applicable provisions of the underlying zone (part 18.2), including but not limited to: building and yard setbacks, lot area and dimensions, density and floor area, lot coverage, building height, building orientation, architecture, and other applicable standards. The proposed Accessory Residential Unit (ARU) complies with the definition of an accessory residential unit from AMC 18.6.1. According to the definition, an Accessory Residential Unit is "Accessory Residential Unit. A secondary dwelling unit on a lot where the primary use is a single-family dwelling, either attached to a single-family dwelling or in a detached building located on the same lot, and having an independent means of access (i.e., door)." The primary use of 692 B Street is a single family dwelling. The proposed ARU is secondary to the use, is detached and has an independent means of access. The ARU will be created utilizing the existing small, 288-square foot upper level of the shop building to create a 385-square foot ARU. The addition of a shed roof dormer will provide the additional square footage without conflict with the Historic Contributing residence. The ARU can be found to comply with the Site Review Standards including the Historic District Design Standards, Landscaping, Lot Coverage, Setbacks, Parking, and other standards for the development of an Accessory Residential Unit. Setbacks: The subject property is zoned R-2, Multi-Family Residential. The residence complies with the minimum setbacks in the zone. The garage/ shop building is pre-existing. It was constructed in the 1990s under permit of the City of Ashland. The structure is setback three feet from the west, side property line and eight feet from the south, rear property line that abuts the alley. The setbacks are not proposed to be altered as part of the proposal. The structure is not attached to any other building. It is less than 15 feet in height and complies with the side and rear yard setback exceptions for Accessory Buildings and Accessory Residential Units abutting an alley. Additionally, the structure is 47 feet wide and three feet from the internal side yard setback, the structure is 50 feet from Sixth Street and therefore complies with the other allowed exception to the side yard setback. Lot Area and Dimensions: There are no alterations to the lot area or dimensions. Density: The proposed accessory residential unit and the primary residence are the only proposed units on the property. The lot area at 13,400 square feet has a potential density of 4.15 dwelling units. The proposed ARU and primary residence fall within the standards for allowed densities. According to AMC 18.2.5.080. B.3. Accessory residential units are not required to meet the density or minimum lot area requirements of this section. See criteria addressing 18.2.3.040 for accessory residential unit standards on the following pages. Maximum Permitted Floor Area: The proposed enlargement of the space within the existing accessory structure and the conversion of it to an accessory residential unit appears to be exempt from the MPFA calculations per AMC 18.2.5.070.E. "detached garages, detached accessory structures, and detached accessory residential units are not counted in the gross floor area for Page 4 of 12 the MPFA calculation if separated from the primary dwelling by six feet or more". The detached garage, and accessory residential unit are more than six feet from the primary residence. The existing structure and the accessory structures (detached garage and greenhouse) account for 2,344 square feet which is less than the maximum allowed of 3,055.2 square feet. 13400 X. 6 = 8,040 (adjusted lot area) 8,040 X.38 = 3,055.2 square feet MPFA Existing SFR: 2,076 square feet Existing detached garage: 288 square feet Existing greenhouse: 80 square feet Existing Total: 2,344 square feet Lot Coverage: No changes are proposed to the existing impervious areas. Impervious areas including building footprints, patios, pathways, driveways, decks are 4,304 square feet. The maximum coverage is the zone is 65 percent the proposed lot coverage. The proposed lot coverage is 32 percent of the total lot area. Building Height: The structure is substantially less than 30 feet in height. Average building height details are shown on the elevation plan. Based on the average building height measurements, the structure is 14.17 feet tall and allows for the reduced setback exceptions as discussed previously. The maximum building height in the historic district is 30 feet. Parking: Three parking spaces are required for the development of the property. A two-vehicle garage is accessed from the alley. An on-street parking credit on Sixth Street is proposed to provide the single parking space for the ARU. Three bicycle parking spaces are required. The bicycle parking spaces are provided for within the garage. Standards for Residential Zones: 18.2.3.040 Accessory Residential Unit Where accessory residential units are allowed, they are subject to Site Design Review under chapter 18.5.2, and shall meet all of the following requirements. 1. One accessory residential unit is allowed per lot, and the maximum number of dwelling units shall not exceed two per lot. One accessory residential unit is proposed. Including the single-family residence, the maximum number of dwelling units will not exceed two per lot. Page 5 of 12 2. Accessory residential units are not subject to the density or minimum lot area requirements of the zone, except that accessory residential units shall be counted in the density of developments created under the Performance Standards Option in chapter 18.39. The lot was created as part of the Railroad Addition. The lot exceeds the minimum lot area in the zone. 3. The maximum gross habitable floor area (GHFA) of the accessory residential unit shall not exceed 50 percent of the GHFA of the primary residence on the lot, and shall not exceed 1,000 square feet GHFA. The proposed accessory residential unit is 385 square feet in area. The primary residence is 2,076 square feet in area, more than 50 larger than the proposed ARU. 4. The proposal shall conform to the overall maximum lot coverage and setback requirements of the underlying zone. Lot Coverage: No changes are proposed to the existing impervious areas. Impervious areas including building footprints, patios, pathways, driveways, decks are 4,304 square feet. The maximum coverage is the zone is 65 percent the proposed lot coverage. The proposed lot coverage is 32% of the total lot area. Building Height: The structure is substantially less than 30 feet in height. Average building height details are shown on the elevation plan. Based on the average building height measurements, the structure is 14.17 feet tall and allows for the reduced setback exceptions as discussed previously. The maximum building height in the historic district is 30 feet. 5. Additional parking shall be provided in conformance with the off-street parking provisions for single-family dwellings in section 18.4.3.040, except that parking spaces, turn-arounds, and driveways are exempt from the paving requirements in subsection 18.4.3.080. E.1. The ARU is less than 500 square feet and requires one parking spaces in addition to the two required for the single-family residence. One additional parking space is proposed as an on-street parking credit on Sixth Street. There is more than 22 feet of uninterrupted street frontage along the Sixth Street frontage. C. R-2 and R-3 Zones. Accessory residential units in the R-2 and R-3 zones shall meet the standards in subsection 18.2.3.040.A, except that the maximum gross habitable floor area (GHFA) of the accessory residential structure shall not exceed 50 percent of the GHFA of the primary residence on the lot, and shall not exceed 500 square feet GHFA. Page 6 of 12 The proposed accessory residential unit is in the R-2 zone and complies with the standards from 18.2.3.040 and the portion of the structure devoted to the accessory residential unit does not exceed 50% of the gross habitable floor area of the primary residence and is less than 500 square feet of gross habitable floor area. 18.2.3.120 Dwelling in Historic District Overlay Dwellings in the Historic District Overlay subject to all of the following requirements. A. Manufactured homes are prohibited. N/A B. Dwellings shall conform to the maximum permitted floor area standards of section 18.2.5.070, except that dwellings exceeding the maximum permitted floor area are allowed subject to approval of a Conditional Use Permit under chapter 18.5.4. The proposed accessory residential unit is exempt from the maximum permitted floor area calculations C. Notwithstanding the height standards of the R-1 zone, structures within the Historic Overlay shall not exceed a height of 30 feet. The average height of both structures is less than 30 feet. D. Retail commercial uses in a dwelling unit within the Railroad Historic Overlay are subject to approval of a Conditional Use Permit under chapter 18.5.4 and shall conform to the standards of section 18.2.3.210. N/A B. Overlay Zones. The proposal complies with applicable overlay zone requirements (part 18.3). The property is within the Ashland Railroad Historic District. The proposed additional 97 square feet of area for the accessory residential unit complies with the standards for additions to structures in the historic district. 18.4.2.050 Historic District Development B. Historic District Design Standards. The property is occupied by a historic contributing, two story, residence. The 1888 built Farra- I` McFarland House is a historic contributing structure. It is not proposed to be altered as part of this proposal. Substantial renovations were completed in the 1990s that added some historically, inappropriate volumes, windows, and roof pitches. The garage /shop building that is proposed to be altered is constructed in the mid-1990s and has similar window and door styles to the additions to the primary residence. I Page 7 of 12 The adjacent properties are developed with single and multi family residences and their accessory structures. Height: The structure has an average height of 14.17 feet. The accessory structure is similar in height as the existing accessory structures in the vicinity. Scale: The scale of the proposed accessory residential unit falls within the allowed size of an accessory residential unit in the R-2 zone. The residence is a similar scale to the other architecture found in the immediate vicinity. i Massing: Through the incorporation of a shed roof the overall massing is similar to the residences in the vicinity. i I Setback: The setbacks are not proposed to be altered as part of the accessory residential unit development. G Roof: The proposed addition of a shed roof dormer is consistent with roof forms found in the E vicinity. Rhythm of Openings: The existing structure and the proposed alteration is consistent with rhythm of openings found on residential structures in the vicinity. E Base or Platform: No changes are proposed to the structure that would alter the base or platform. Form: The form of both the single-family residence and the ARU are traditional residential farms found throughout the Railroad Historic District. E Entrances: The primary residence has an entrance that faces the public street. Due to the substantial setback of the accessory residential unit from the public streets, there is not a requirement for a visible entrance. The entrance to the ARU will be to the left of the garage doors in the small courtyard area between the rear property line and the door of the ARU. Imitation: The proposed dormer addition has elements of traditional cottage design, vernacular architecture and craftsman styles. Though there are a variety of housing styles in the vicinity. Vernacular 1-home, craftsman and American bungalow cottage style construction are found throughout the Railroad historic district. Garage Placement: The garage is existing, no changes to placement of garage are proposed. t Page 8 of 12 `t C. Site Development and Design Standards. The proposed site development complies with the applicable Site Development and Design Standards of part 28.4. The layout and design does not provide vulnerable areas that are not visible from the units and open space. The trash / recycle areas are near the public street for easy access and will be screened in accordance with the screening standards. The cans will not be visible from the public right-of-way. Any new exterior lighting will be appropriately shrouded and will not directly illuminate adjacent properties. No plant materials are proposed that prevent surveillance of the open space or the semi- private patios and balconies. The proposed development requires 2,072 of open space for the tenant. More than eight percent of the site is available as open spaces for the use of the property owner and tenant. There is 168 square feet front porch and more than 4,000 square feet of lawn area for the primary residence. A small yard area to the east of the garage will be provided for the tenant of the ARU. There is also a small courtyard between the entrance of the ARU and the rear property line (approximately 80 square feet). Building Orientation. Building Orientation to Street. Dwelling units shall have their primary orientation toward a street. Where residential buildings are located within 20 feet of a street, they shall have a primary entrance opening toward the street and connected to the right-of-way via an approved walkway. The primary residence is oriented towards B Street. The accessory residential unit is oriented towards the alley. The new shed dormer will add interest and orientation to the Sixth Street fagade. The accessory residential unit is more than 20 feet from the street and is not connected to the right-of-way via an approved walkway. The entrance to the ARU is oriented towards the alley and has an ten foot setback to the existing six foot fence that is parallel to the rear property line. Limitation on Parking between Primary Entrance and Street. Automobile circulation or off-street parking is not allowed between the building and the street. Parking areas shall be located behind buildings, or on one or both sides. No parking is proposed between the structure and the street. Automobile circulation is from the alley. Build-to Line. Where a new building is proposed in a zone that requires a build-to line or maximum front setback yard, except as otherwise required for clear vision at intersections, the building shall comply with the build-to line standard. There is not a build-to or maximum setback line in the R-2 zone. Page 9 of 12 Garages. Alleys and Shared Drives. Where a lot abuts a rear or side alley, or a shared driveway, including flag drives, the garage or carport opening(s) for that dwelling shall orient to the alley or shared drive, as applicable, and not a street. i i The primary vehicular access to the site is via the public alley at the rear of the property. The existing garage/shop building faces the alley. This orientation will not be modified as part of this proposal. Setback for Garage Opening Facing Street. The minimum setback for a garage (or carport) opening facing a street is 20 feet. This provision does not apply to alleys. The garage is preexisting and faces the alley not the street. Building Materials. Building materials and paint colors should be compatible with the surrounding area. Very bright primary or neon-type paint colors, which attract attention to the building or use, are unacceptable. The structure is largely existing. The proposed change is from an existing gable to a shed roof to increase useable floor area. The building materials are to match the existing garage structure and the existing historic contributing structure. The materials are compatible with the surrounding area. The materials are typical building materials such as hardi-plank, lap siding and cedar siding accents in the gables are proposed. The structures will all be repainted. The exact paint colors have not been selected but they will not be bright primary or neon colors. Streetscape. One street tree chosen from the street tree list shall be placed for each 30 feet of frontage for that portion of the development fronting the street pursuant to subsection 18.4.4.030.E. Street trees exist along both street frontages. Landscaping and Recycle/Refuse Disposal Areas. Landscaping and recycle/refuse disposal areas shall be provided pursuant to chapter 18.4.4. Area for a trash and recycle container is proposed adjacent to structure. The area will be screened to prevent view of the cans from the public street. Landscaping and Screening No changes are proposed to the landscaping. All landscaping shall be maintained in good condition and replaced by the property owner if damaged during the course of construction. The ?aid I Page 10 of 12 t sewer, water and electric service exist for the structure and no excavation for services is anticipated, limiting site disturbance. D. City Facilities. The proposal complies with the applicable standards in section 18.4.6 Public Facilities, and that adequate capacity of City facilities for water, sewer, electricity, urban storm drainage, paved access to and throughout the property, and adequate transportation can and will be provided to the subject property. Adequate city facilities exist to service the existing structures and the new accessory residential unit. Water. The existing structure is served with water service from a meter on the 8 Street side of the property. This water service will continue to be utilized for the existing structure and the new accessory residential unit service. Sanitary Sewer. The existing structure is connected to sanitary sewer. This line will be utilized for the accessory residential unit. Electrical. New electric services will be installed on the property in conjunction with the needs of the Ashland Electric Department. The attached plan shows the preliminary electric layout with a new meter being placed adjacent to the existing meter on the south side of structure facing the alley. Storm Sewer. There are stormwater sewer mains in 8 Street and Sixth Street. In consultation with the Public Works Dept., there are no capacity issues with the city's facilities. Conclusion: The proposal appears to comply with the height, setback, historic district design standards, parking, coverages and all other applicable City of Ashland standards for the construction of an accessory residential unit in the R-2 zone. Attachments: 1) Photograph of existing garage /shop building 2) AS1.0 - SITE PLAN 3) A2.1- ELEVATIONS i Page 11 of 12 i i t i f i I VIEW FROM SOUTHWEST Vy I' Page 12 of 12 W IAN ST VICINITY MAPS 9TFOF0~~~ PRK ROW PRK ROW y o 0 o N F.H. yp ~i 8. 0 KNv WIVI 0 u PROPERTY LINE 100' sw ="a Aqr ° I- T v m a s U Q v Y Mq y W Protection of Existing and Proposed Trees 4 ti C o z sw q d Sr, Uj H A. Landscape adjacent to the project area shall be protected from LL g~ D EDRE A t damage, No storage of equipment or materials shall occur within drip AAA 7:14 U o ~ lines caused b preserved = 1896 N~ W construction hto existing trees shall be compensated ' LL damage by EARL g a for, before the project will be considered completed. a B. Trees that are shown on the plans to remain shall be protected with fencing as shown on plans. Fencing shall be 6' tall temporary chain link sw s o p E panels installed with metal connections so that all panels area integrated, ~~ti sA o gscHoHOL j these fences shall be installed so that it does not allow passage of LL DwA p s, pedestrians and/or vehicles through it. ~ C. Exceptions to the tree protection specifications may only be granted in 11 I ( b o f o a~ extraordinary circumstances with written approval from owners L ~7 al ~ryoo LINCOLN fig p representative. 1897 (F) ~I GRADE ( a ¢ PE unvauIA o - - SCHOOL D. Pieces of work that will require disturbance of tree protection fences - STORY TWO Include: the following: ~I REASIDENCE, v 1) when tree roots over 2" are cut due to required site work, cut cleanly tl w at a 90 d egree angle to the root. 692'B' STREET 2) Place damp soil around all cut roots to a depth equaling the exiting ZONE: R2 / .31 ACRE PROJECT SITE finish grade within 4 hours of cuts being made 39 1 E-09AB; T.L.# 7000 F. Do not raise the soil level within the drip tins of existing trees to achieve positive drainage, except to match grades with sidewalks and J z CITY OF ASHLAND curbs, and In those areas feather the added topsoil back to existing z a9a„ J grade at an approximately 3:1 slope. I Sw } 3: G Inspection Schedule: F ° 1) Fencing locations and installation technique shall be approved by ,i J 8 owner's representative before demolition or rough grading begins. W tl _ a (E) W o a- , STORAGE 0 z 2) Routine inspections of fencing and site conditions will occur on a 0 PATIO 0 z o z_t CL P L A N N I N G S U M M A R Y weekly basis, work shall cease if fencing is damaged or moved w i k h e u t ~ written prior approval for specific parts ofwork D 3) At completion of project to determine ultimate condition of trees, SIDE r' 1699{ r 4) To determine further measure to ensure tree survival or replacement PROT EEION GR . II n/ z~ P m 3'-0 (E)STRUC - i~ 5"O COFFEE PROPERTY DESCRIPTION: ofWp1 Q at end of project" 3'-0 i 25 H'sE ZONING DESIGNATION: R2 zofm o I 24-0" ASSESSOR'S PARCEL NUMBER: 39-1E-09AS:T.L.970M _J 0 W =8N!<~ 692'B' STREET, ASHLAND, OREGON 97520 0 - p m ~mZ m - - FE 'N - IV-O^CRNR d) LOT COVERAGE SUMMARY: W0) 0 SIDE SieK EE 3 t Z W= Z 5"0 COF 2 !Pe SL Z Q d I q (E) BUILDING FOOTPRINTS SW r"°-~1-, (E) DRIVEWAY & WALKS & PATIOS: 1,2H8 FF LL1 0 Q Y <8 Sr 2 PLAN i i e ELEVATION X g (E) PORCHES L ` TIE INTO (ET d 1 ti -945F ® W aI ANDSS ATG ETOTAL EXISTINOLOTCOVERAGB: of C, TOTAL LOT AREA: 13,900 SF (.31 ACRE) W 8,T10SF W pENCe coREE PER lv TOTAL LOT COVERAGE ALLOWED 65%: (E)SINGLE DESIGNATED 1900TOTAL EXISTING LOT COVERAGE%(4,304 SF13,400 SF): 32% N -11 AAWNDTAEEPER III p~EO CONSTRUCTION Q PLAN ~j o~ ~o STORY SHOP (1.f / R', Yr, STAGING&THEN 1 ARID ARU -YARDUSE AREA 4 BUILDING AREA PLANNING SUMMARY: ~-6-ThEtONTIN000S - -1-----_--` I (E) MAIN HOUSE: 2,076 SF I J CHANLINKFENCNGCN -,s w NOTE: CONCRETE PIERS GASMTR j' TB SW (E) SINGLE CAR GARAGE: 220 SF NOT FOR CONSTRUCTION ELECT (DRS.-°1 (EISHED. 80 SF 1. TREE PAOTECnIXI FENCING SHALL BENSTALLED PRIOR T0START OF CONSTRUCTION AH0SHALL ftEMNNN PLACE L 17~" TpYARD u~ (E)TwO CAR GARAGE: 636 SF THROUGH COMPLETION OF PROJECT. i ROUTE I III ~ 1901' T FENCING SHALL ONLY BE REMOVED TEMPORARILY FOR WORKTO BE DONEWNHN DRIPLNEAND REPLACED AT THE S (E) SHOP (LOWER FLOOR): 352 SF END of EACH WORK DAY. (E) SHOP (UPPER FLOOR >7' HT.): 288 SF 3. ALL EXCAVATION WITHIN DRIPLNE OF TREES SHALL BE DONE BY HAND. IF ROOTS OVER 2'N DIAMETER ARE (E) PWR POLE PROPERTY LINE 100' (E) TOTAL 3,652 SF DRAWN: CHECKED: ENCOUNTERED, CONTRACTOR SHALL CONSULTWNH IANDSCAPEARCHRECTOR ARBO.RISTBEFORE PROCEEDING, TS A TREEROOTS ENCOUNTERED DURNGCCVSTRUCTIDNUNDER TDAMETER,6HALLBECUTCLEANLYATA90DEGREE TS CD ANGLE AND PACKED WITH DAMP SOIL IMMEDIATELY, - GAS- GAS- GAS- GAS- GAS- GAS- GAS- CAS- GAS- GAS- GAS GA - GAS 5.DURNG CONSTRUCngiau TREES TO REMAIN SHALL BE NRIGATED CH AWEEKLY BASIS ORA$NECESSARY. (P) SHOP CONVERTED TO ARU(UPPER FLOOR>7'HT.): 385 SF CO DATE: 1 TREE PROTECTION A L L E (P)ADDIroNALTOTAL: 97 SF a 07107117 x OFF STREET PARKING SUMMARY: WIX PROJECT: 3 BEDROOM DWELLING REQUIREMENT: 2 (E) SPACES a RINALDI 17 NORTH 385 SF ARU UNIT REQUIREMENT', i (P) ON STREET SPACE F - W SHEET: AVERAGE BUILDING HEIGHT: U) S I T E PLAN - - ~NORTH r EAST & SOUTH SIDE AVG, HTS: (3)14.75' n 1°-10'0" WESTSIDE AVG. HT: (1) 12,42' A1.0 AVG. ALL (4) SIDES: 14.17' 0 10 z0 30 OF SHEETS L' I c ' II 9TFOF0~~ - - - - - - - - - - - - - - - - - - - - - - - - - - - - ®~E sTO1. ~ i ~ II j ❑I~rS ~ ~ itf m BATH p rn y a -4I v .4. _ A3, ~W N 0 = L ------------m®.V Elk OPEN ROOM +67 r®I r o 4 4-d U c f ff A I ~ r ~ \ m I i I+ CLOSET \V j ISTOR. ' N" 21A1 L. Q \ I I F REP O I: :I :I i i T N z 0 - - - - - - - - - - - - - - - - C EXISTINGWALLSTOREMAIN I 1 EXISTING WAILSTOREMAIN W NEWWALLB NEW WALLS C) F7 C=1 WALLS TO BE REMOVED ✓'a C] WALLS TO BE REMOVED ROOF PLAN UPPER FLOOR PLAN SCALE: 1)4'-V-0' NORTH SCALE: 1/4°=rm NORTH l € I 0 4 8 12 0 4 8 12 L!J o ® z - o OC aim Q E TLT E S() TORAGE z W 00) W -atoZ a; g 1 ! I ~ CLC+B' - P WN O z~N z I (•)6.6' 1-)eb- CLG+8'8 z w i t Q Q 03 CLEAR 6~L1 N HEADROOM ---------JI------------ - N 7 C-. Q EI ) SHOP ACCAESS t4' HDRM CLG N4'6 BELOW (E) GARAGE ~I NOT FOR CONSTRUCTION I i n DRAWN : CHECKED: ' TS CD '(E)OA8) UP `r l 8R@7.5- (CAMP III j DATE; v ENTR PANEL (•)7s 07107/17 m PROJECT: [j&AS (E) ELECT a RINALDI17 MfR E~ EXISTING WALLS TO REMAIN to NEW WALLS z SHEET WALLS TO BE REMOVED W MAIN FLOOR LAN A1'1 SCALE: 114- 1-T NORTH OF SHEETS 0 4 8 12 A al 8 'MOON PI, 'c' V 9TFOF Re zza" (P) SHED DORMER (P) SHED DORMER u rV-4' O 1.5 O L 12 L. II l l it n (M WINDOW (N) t c) r N (N) r 1~U IN) SHED DORM ER O J ~1~ 111 I .I- I-E.~ (M (E)4SIDED GABLE W I III ~ II , I-f11..~ (E)OABLEOUTLINE ~I. _ (VI I-lt4 (c~WINDOWTO BE - E( J r - REMOVED I - - - T m ® N U - - - c 4-4 0 - ' _ - - - E r _ j 9rc, ~J ~~I ~JI ~I' i m a ( _ III (E)WINDOW EhI `ac I, (E)'1 1JI~li _;I I~EYIIi a I( - E I- ---jjjj~ ~I ~ i EAST ELEVATION (FACING Sm ST.) NORTH ELEVATION (FACING 'R ST.) I SCALE: 1/4"=P-0" SCALE: 114"=1'-0" 0 i iI o a s tz o a a iz J I fi u i Ili o ® Z J O ° iT-iP (P) SHED DORMER Ldo w O) w O _ zW ` = W - ONz p 'I ~ll' ;,l~~Tlln - ~mz m FM h Y1 r` ii JJI4.{ _ Z z a Q s l 4u t - m - J PI _1, 1'ill~I~ _ IP E - ~ I _ , f~ lug I III ie i J 1_Il I I I- I~ - N - - N --T LL ¢ lu I I , - - - C - t U 4 E) 11 (N) ~II'~ >a _ .J _ t~(E~JI I 1 ~ (E'' I NOT FOR CONSTRUCTION 1~~ L - i ~ II 1 I I ~ - - 1t i~ I - --.._I i - - -::1. DRAWN: CHECKED: P EMR 1 co n{ TS D DOOR (P) SINGLE CAR GARAGE DOOR DATE:: SOUTH ELEVATION (FACING ALLEY) WEST ELEVATION 07107/17 SCALE: 114"=1'-0" SCALE: 114"=1'-0" PROJECT; RINALDI_17 W SHEET: A2.1 OF SHEETS i Job Address: 692 B ST Contractor: ASHLAND OR 97520 Address: i C A. Owner's Name: RINALDI JOHN R JR/BONNIE J ® Phone: N State Lic No: ~ Customer 09420 P RINALDI JOHN R JR/BONNIE J T City Lic No: Applicant: PO BOX 91057 R Address: HENDERSON NV 89009 A C C Sub-Contractor: A Phone: T Address: N Applied: 07/06/2017 T Issued: Expires: 01/02/2018 Phone: State Lic No: Maplot: 391 E09AC3400 City Lic No: DESCRIPTION: Slte Deign review forARU VALUATION Occupancy Type Construction Units Rate Amt Actual Amt Constuction Description Total for Valuation: MECHANICAL ELECTRICAL STRUCTURAL PERMIT FEE DETAIL Fee Description Amount Fee Description Amount Residential Site Review 1,115.00 CONDITIONS OF APPROVAL COMMUNITY DEVELOPMENT Tel: 541-488-5305 20 East Main St. Fax: 541-488-5311 Ashland, OR 97520 TTY: 800-735-2900 www.ashland.or.us CITY Request Line: 541-552-2080 F LAN D r I hereby certify the contents of this application to be correct to the best of my knowledge, and furthermore, that I have read, Fee Summary Paid Amounts understood and agreed to the following: Building: $ 0.00 $ 0.00 1. This permit shall remain valid only in accordance with code State Surcharge: $ 0.00 $ 0.00 or regulation provisions relating to time lapse and revocation (180 days). Development Fees: $ 0.00 $ 0.00 . 2. Work shall not proceed past approved inspection stage. All Systems Development Charges: $ 0.00 $ 0.00 required inspections shall be called for 24 hours in advance. Utility Connection Fees: $ 0.00 $ 0.00 3. Any modifications in plans or work shall be reported in advance to the department. Public Works Fees: $ 0.00 $ 0.00 4. Responsibility for complying with all applicable federal, state, Planning Fees: $ 1,115.00 $ 1,115.00 or local laws, ordinances, or regulations rests solely with the applicant. Sub-Total: $ 1,115.00 Fees Paid: $ 1,115.00 Applicant Date Total Amount Due: $ 0 COMMUNITY DEVELOPMENT Tel: 541-488-5305 20 East Main St. Fax: 541-488-5311 Ashland, OR 97520 TTY: 800-735-2900 www.ashland.or.us Inspection Request Line: 541-552-2080 CITY F S Hff LAN D"