Loading...
HomeMy WebLinkAbout2929 Oregon Fire Code ORDINANCE NO. 2929 AN ORDINANCE AMENDING THE ASHLAND MUNICIPAL CODE RELATING TO ADOPTION OF THE 2004 OREGON FIRE CODE. THE PEOPLE OF THE CITY OF ASHLAND DO ORDAIN AS FOLLOWS: Section 1. Ashland Municipal Code Chapter 15.28 is amended to read as follows: Chapter 15.28 FIRE PREVENTION CODE Sections: 15.28.010 15.28.020 15.28.030 15.28.040 15.28.050 15.28.060 15.28.070 15.28.080 15.28.090 15.28.100 15.28.110 15.28.120 15.28.130 15.28.140 15.28.150 15.28.160 Adoption Of Oregon Fire Code. Establishment of Duties. Definitions. Above-ground Storage of Flammable or Combustible Liquids. Storage of Liquefied Petroleum Gases - Restricted. Storage of Explosives - Prohibited. Amendments to the Oregon Fire Code Appeals. New Materials, Processes, or Occupancies - Permits Required. Penalties. Severability . Firefighting Outside City - Authorized. Firefighting Outside City - Resources. Firefighting Outside City - Assessment. Plan Review/Permits - Fees. Code Compliance Inspection - Fees. SECTION 15.28.010 Adoption Of Oregon Fire Code. The 2004 Oregon Fire Code and appendices A through L & SR are hereby adopted, except where specifically excluded or modified by this section. The 2004 Oregon Fire Code and all appendices, as excluded or modified by this section, will be referred to in the Ashland Municipal Code as the Oregon Fire Code. One copy of the Oregon Fire Code and appendices shall be filed in the office of the City Recorder. SECTION 15.28.020 Establishment of Duties. The Oregon Fire Code shall be enforced by the Fire Code Official as defined by the Oregon Fire Code. SECTION 15.28.030 Definitions. A. Wherever the word "jurisdiction" is used in the Oregon Fire Code, it is the City of Ashland. Wherever the words "Bureau of Fire Prevention" are used, they shall mean ~r-- "Fire & Life Safety Division." SECTION 15.28.040 Above-ground Storage of Flammable or Combustible Liquids. The limits referred to in Section 3404.2.9.5.1 of the Oregon Fire Code in which the storage of flammable or combustible liquids is restricted are established as follows: All City of Ashland residential and historical district areas as defined in the Comprehensive Plan. SECTION 15.28.050 Storage of Liquefied Petroleum Gases - Restricted. The limits referred to in Section 3804.2 of the Oregon Fire Code, in which storage of liquefied petroleum gas is restricted, are established as follows: All City of Ashland residential and historical district areas as defined in the Comprehensive Plan are limited to the aggregate capacity of anyone installation shall not exceed a water capacity of 500 gallons. In particular installations, this capacity limit shall be determined by the Fire Code Official, after consideration of special features such as topographical conditions, nature of occupancy, and proximity to buildings, capacity of proposed containers, degree of fire protection to be provided and capabilities of the City of Ashland Fire & Life Safety Division. SECTION 15.28.060 Storage of Explosives - Prohibited. The limits referred to in Chapter 3301.2.3 of the Oregon Fire Code, in which storage of explosives and blasting agents is prohibited, are established as follows: All areas within City of Ashland limits. SECTION 15.28.070 Amendments to the Oregon Fire Code The Oregon Fire Code is amended in the following respects: A. Section 503.2.5 Dead Ends: Change 150 feet in length to 250 feet in length. B. Section 506.1 Replace the second sentences as follows: The key box shall be of an approved type, installed and maintained in accordance with manufacturers instructions, and shall contain keys to gain necessary access as required by the fire code official. C. Section 508.5.1 & Exceptions Delete and replace with the following: The approved fire apparatus operating area must be located within 300 feet from a hydrant, as measured by an approved route, along an approved driving surface. With the installation of an approved automatic fire sprinkler system, hydrant distance may be increased to 600 feet. D. Section 3301: Notwithstanding the exceptions listed in this section, the sale of DOT classification 1.4G (Class C common fireworks) is prohibited within the City of Ashland. The use of common fireworks within the City of Ashland is prohibited during any declared fire season except when the sale of fireworks is permitted within the State of Oregon pursuant to ORS 480.127 (June 23 to July 6 of each year). (Ord 2871,2001; Ord 2876, 2002) E. Appendix B, section 105.1: Replace the entire section as follows: The minimum fire flow requirements for one- and two-family dwellings having a fire-flow 2 --,--- ----~-- calculation area which does not exceed 3,600 square feet shall be 750 gallons per minute. Fire flow and flow duration for one and two-family dwellings having a fire-flow calculation area in excess of 3,600 square feet shall not be less than that specified in Table B105.1." "EXCEPTIONS": 1. A reduction in required fire flow of 50 percent, as approved by the Fire Code Official, is allowed when the building is provided with an approved automatic fire sprinkler system. 2. One and two-family dwellings in excess of 3,600 square feet, when equipped with an approved automatic sprinkler system, may have a minimum flow of at least 375 gallons per minute. If minimum fire flow as specified in table B105.1 cannot be met after the 50% reduction credit is applied, then the fire sprinkler system shall be monitored by an alarm company. F. Appendix 0105.1 Change first sentence as follows: Buildings or portions of buildings or facilities exceeding 24 feet in height above the lowest level of fire department vehicle access shall be provided with approved fire apparatus access roads capable of accommodating fire department aerial apparatus. SECTION 15.28.090 New Materials, Processes, or Occupancies - Permits required. The Building Official, the Chief and the Fire Marshal shall act as a committee to determine and specify, after giving affected persons an opportunity to be heard, any new materials, processes or occupancies for which permits are required in addition to those now enumerated in the Oregon Fire Code. The Building Official, in accordance with section 104.9 of the Oregon Structural Specialty Code, shall record and enter in the files of the building department any action granting approval of new or alternate materials. SECTION 15.28.100 Penalties. A. Any person who violates any of the provisions of this chapter, the Oregon Fire Code or as adopted in this chapter or who shall violate or fail to comply with any order made thereunder, or who shall build in violation of any detailed statement of specifications or plans submitted and approved thereunder, or any certificate or permit issued thereunder, and from which no appeal has been taken, or who shall fail to comply with such an order as affirmed or modified by the Ashland Appeals Board or by a court of competent jurisdiction, within the time fixed herein, shall severally for each and every such violation and noncompliance, respectively, be guilty of a violation punishable by a fine as set forth in Ashland Municipal Code, Section 1.08.020. The imposition of one penalty for any violation shall not excuse the violation or permit it to continue: and all such persons shall be required to correct or remedy such violations or defects within a reasonable time; and when not otherwise specified, each ten days that prohibited conditions are maintained shall constitute a separate offense. 3 B. The application of the above penalty shall not be held to prevent the enforced removal of prohibited conditions. SECTION 15.28.110 Severability. Should any section, paragraph, sentence or word of this ordinance or of the Code or Standards hereby adopted be declared for any reason to be invalid, it is the intent of The City of Ashland that it would have passed all other portions of this ordinance independent of the elimination here from of any such portion as may be declared invalid. SECTION 15.28.120 Firefighting Outside City - Authorized. In accord with ORS 476.290, the Fire Chief or representative is authorized to extinguish uncontrolled fires that are found to be burning in unprotected areas situated outside the boundaries of the City and that are causing or may cause an undue jeopardy to life or property if, in the opinion of the Fire Chief or representative, such fire is causing or may cause an undue jeopardy to life or property. (Ord. 1698 S 1, 1971) SECTION 15.28.130 Firefighting Outside City - Resources. In extinguishing a fire pursuant to Section 15.28.120, the Fire Chief or representative may employ the same means and resources used by them to extinguish similar fires within the City. SECTION 15.28.140 Firefighting Outside City - Assessment. Whenever a fire is extinguished or attempted to be extinguished by the fire department outside the City of Ashland, the owner of the property involved in such fire shall pay for the cost of providing such fire suppression service, as follows: A. For the first hour or fraction thereof: 1. Pumper apparatus - $250.00/hour 2. Brush apparatus - $100.00/hour 3. Rescue standby - $100.00/hour 4. Staff vehicle - $ 50.00/hour For each piece of apparatus per hour following the first hour, payment shall be on a fractional basis to the nearest 15 minutes. B. Personnel cost shall be actual cost with a minimum charge of one hour for each person responding to the fire emergency, plus all personnel costs in excess of regular time for each person performing standby services in place of those who respond, to be billed on a fractional basis to the nearest fifteen minutes after the first hour for any fractional portions of hours of service. (Ord. 2711, 1993) SECTION 15.28.150 Plan Review/Permits - Fees. For application in this city, Oregon Fire Code plan review fees shall be established by resolution of the city council. 4 SECTION 15.28.160 Code Compliance Inspection - Fees. The schedule for fire code compliance inspections shall be established by resolution of the city council. The foregoing ordinance was first read by title only in accordance with Article X, Section 2(C) of the City Charter on the I day of tiu ~ and duly PASSED and ADOPTED this j,f day of ~ ,2006, ,2006. Barbara Christensen, City Recorder SIGNED and APPROVED this \ ~ day of ( <::...-- 5 ~